Serial Data Format $Revision: 4.41
----------------------------------
WattsUp? communicates with the outside world over a standard RS232 serial port.
The following section gives technical specification for the communication
protocol. This can be useful to programmers or other people who have special
needs. Ordinary users can skip over this section.

I. DATA FORMAT. 
===============
All commands and data packets have the following format.

1. Serial Format. Data is transmitted and received as standard RS232 data at
115200 baud, 8 data bits, 1 stop bit and no parity bit.

2. Character Format. Data consists of standard ASCII characters. Numbers are
represented as strings of ASCII characters with no binary numbers.

3. Packets. All information is contained in packets. All characters outside of
a packet are ignored. Packets begin with a pound sign "#" and end with a
semicolon ";".

4. Arguments. Inside the packet are a series of arguments. Arguments can be
strings or ASCII representations of numbers. Arguments are separated by commas
",". The last argument is terminated by the semicolon ";". No empty arguments
are allowed. Each argument must have at least one character. For numerical
arguments, the argument must be a valid ASCII Number (hex 30 through hex 39).
String arguments must contain at least one character, even if it is just a
space. Control character such as Carriage Return, Line Feed and Tab characters
are ignored within a packet. Spaces are valid characters inside string
arguments.

Any argument other than Subcommand (see next) which intentionally has no value
is represented by an underscore "_". For example data record arguments
following "#d" will contain "_" for every value that was unlogged.

5. Commands. The first two arguments are single ASCII characters representing a
Command and Subcommand. Commands and Subcommand specify an action to be carried
out or specify the type of data in the packet. Commands to the WattsUp meter
from the host (PC, Mac, etc.) are generally upper case. Replies from the
WattsUp meter to the host are generally lower case. If there is no Subcommand,
any ASCII character can be used, but a dash "-" is generally preferred.

6. Argument Count. The third argument is a numerical value that represents the
number of arguments that follow. The two commands and the count itself are not
included in the count.

7. Transactions. All data transfers are initiated by the host. In other words,
WattsUp never sends data to the host unless the host makes a specific request.
There is just one exception to this general rule: at reset (normally occurring
only at power-on startup), the WattsUp meter emits an unsolicited announcement
heralding its firmware name, version, compilation date, and the principal
electrical configuration detected: nominal line frequency Hz and nominal
voltage.

Example:
EED05F01 $Revision: 4.41 $ 200612212301 60Hz 120V

8. Syntax Diagram.
#<C1>,<C2>,<Nm>,<A1>,<A2>,...<An>;
<C1> = First Command
<C2> = Second Command
<Nm> = Number of Arguments
<A1> = Individual Arguments

8. Examples.
#U,R,0;
#u,-,3,80,100,0;

9. Timeouts. The Meter will be expected to respond within two seconds of a
request. If no response is received by the PC within two seconds, the software
will timeout and it will be assumed that the Meter is not connected or is
malfunctioning.

10. Aborting Meter Communication. Sending Control-X character (hex 18) to the
meter will cause it to abort any pending communication.

II. Commands and Replies, and <argument> formats
================================================
Command: chosen fields request
------------------------------
#C,R,0;
#c,-,18,<0|1>,...;
Command: chosen fields request
Reply: chosen fields now set to be logged. Each argument is either 0 or 1. 
Notes: The arguments correspond to the Header Record reply list.

Command: Choose list of fields to be logged
-------------------------------------------
#C,W,n,<0|1>,<0|1>,...;
#n,-,1,<Limit>;
Command: Choose list of fields to be logged from now on
Note: clears logging memory, even if change was "no change".
Reply: record count limit using these chosen fields.
<Limit> integer may be approximately 1,700 - 262,000 depending upon choices and
model features.

Command: Data request for all data logged
-----------------------------------------
#D,R,0;
#n,-,3,<Reserved>,<Interval>,<Count>;
#d,-,18,<W>,<V>,<A>,<WH>,<Cost>,<WH/Mo>,<Cost/Mo>,<Wmax>,<Vmax>,<Amax>,<Wmin>,<Vmin>,<Amin>,<PF>,<DC>,<PC>,<HZ>,<VA>;
#l,-,2,<Reserved>,<Interval>;
Command: Data request for all data logged in the WattsUp data memory
Reply: Data Preamble Record. This preamble record is sent before the main data record.
Reply: Data records. Non-chosen fields reported as "_" (underscore).
Reply: Last record of data transfer.
<Interval> integer seconds between logged values

Command: Request WattsUp calibration factors
--------------------------------------------
#F,R,0;
#f,-,48,<Edition>,<NonvolatileStructureVersion>,<50HzIsCalibrated>,<50HzVRMSperVolt>,<50HzIRMSOS>,<50HzVRMSOS>,<50HzCH1OS>,<50HzCH2OS>,<50HzWattsPerAENERGYslope>,<50HzWattsPerAENERGYoffset>,<50HzVoltampsPerVAENERGYslopeUpper>,<50HzVoltampsPerVAENERGYoffsetUpper>,<50HzMidPowerVAENERGYperSecond>,<50HzVoltampsPerVAENERGYslopeLower>,<50HzVoltampsPerVAENERGYoffsetLower>,<50HzLowPowerVAENERGYperSecond>,<50HzIRMSperAmpSlopeUpper>,<50HzIRMSperAmpOffsetUpper>,<50HzMidPowerIRMS>,<50HzIRMSperAmpSlopeLower>,<50HzIRMSperAmpOffsetLower>,<50HzLowPowerIRMS>,<50HzIRMSnoLoadBias>,<50Hzs24LAENERGYperSecondNoLoadBias>,<50Hzs24LVAENERGYperSecondNoLoadBias>,<60HzIsCalibrated>,<60HzVRMSperVolt>,<60HzIRMSOS>,<60HzVRMSOS>,<60HzCH1OS>,<60HzCH2OS>,<60HzWattsPerAENERGYslope>,<60HzWattsPerAENERGYoffset>,<60HzVoltampsPerVAENERGYslopeUpper>,<60HzVoltampsPerVAENERGYoffsetUpper>,<60HzMidPowerVAENERGYperSecond>,<60HzVoltampsPerVAENERGYslopeLower>,<60HzVoltampsPerVAENERGYoffsetLower>,<60HzLowPowerVAENERGYperSecond>,<60HzIRMSperAmpSlopeUpper>,<60HzIRMSperAmpOffsetUpper>,<60HzMidPowerIRMS>,<60HzIRMSperAmpSlopeLower>,<60HzIRMSperAmpOffsetLower>,<60HzLowPowerIRMS>,<60HzIRMSnoLoadBias>,<60Hzs24LAENERGYperSecondNoLoadBias>,<60Hzs24LVAENERGYperSecondNoLoadBias>;
Example:
#f,-,48,13,0,0,3690,0,0,0,0,252,919,252,919,1,252,919,0,100,0,1234,100,0,0,0,0,0,0,3690,0,0,0,0,252,919,252,919,1,252,919,0,100,0,134,100,0,0,0,0,0;
Command: Request WattsUp calibration factors
Reply: all calibration factor values.

Command: Header record request
------------------------------
#H,R,0;
#h,-,18,W,V,A,WH,Cost,WH/Mo,Cost/Mo,Wmax,Vmax,Amax,Wmin,Vmin,Amin,PF,DC,PC,Hz,VA;
Command: Header record request
Reply: Header record with the shown text.

Command: Set the WattsUp to external Logging
--------------------------------------------
#L,W,3,E,<Reserved>,<Interval>;
#d,...
Command: Set the WattsUp to external Logging with this interval
Reply: logging output records

Command: Set the WattsUp to internal Logging
--------------------------------------------
#L,W,3,I,<Reserved>,<Interval>;
#s,-,3,<Reserved>,<Interval>,1;
Command: Set the WattsUp to internal Logging with this interval
Reply: interval used for logging.
Note: clears logging memory.
Note: Interval is ignored if memory-full option is automatically-condensing
<Interval> integer seconds between logged values

Command: Request record count limit
-----------------------------------
#N,R,0;
#n,-,1,<Limit>;
Command: Request record count limit
Reply: record count limit using fields chosen in #C,W command.
<Limit> integer may be approximately 1,700 - 262,000 depending upon choices and
model features.

Command: Request the memory-full handling option
------------------------------------------------
#O,R,0;
#o,-,1,<FullHandling>;
Command: Request the memory-full handling option for when logging memory is filled
Reply: memory-full handling option in effect.

Command: Set the memory-full handling option
--------------------------------------------
#O,W,1,<FullHandling>;
Command: Set the memory-full handling option for when logging memory is filled
Note: clears logging memory, even if change was "no change".
<FullHandling> is logging procedure when logging memory is filled
= 0 stop/suspend means logging suspends until memory is cleared
= 1 wrap/overwrite means logging overwrites oldest (wraparound); most-recent N
records always available
= 2 automatic/condensing means interval always starts at 1 second; at every
memory-full condition interval is doubled (frequency is halved), and logged
data is condensed by one-half, repeatably; oldest (earliest) record always
available.

Command: Reset (clear) the WattsUp data memory
----------------------------------------------
#R,W,0;
Command: Reset (clear) the WattsUp data memory
Note: logging immediately restarts into empty memory space whenever memory is cleared.
Note: whenever automatic/condensing mode is in effect, any memory clear resets logging interval to 1 second

Command: Request current sampling interval
------------------------------------------
#S,R,0;
#s,-,3,<Reserved>,<Interval>,<LoggingNow>;
Command: Request current sampling interval
Reply: interval used logging, current logging state.
<LoggingNow> current status of logging
= 0 means internal logging suspended because memory is full
= 1 means internal logging proceding
= 2 means external logging proceding

Command: Set sampling interval
------------------------------
#S,W,2,<Reserved>,<Interval>;
Command: Set sampling interval
Note: clears logging memory, even if change was "no change".
<Interval> integer seconds between logged values

Command: User parameters request
--------------------------------
#U,R,0;
#u,-,3,<Rate>,<Threshold>,<Euro>;
Command: User parameters request
Reply: User parameters in effect.

Command: User parameters set
----------------------------
#U,W,3,<Rate>,<Threshold>,<Euro>;
Command: User parameters set
<Rate> Cost per KWH, mils (tenths of penny); 0 - 65500.
<Threshold> Duty cycle threshold, watts (units); 0-5000.
<Euro> currency symbol displayed in LCD
= 0 means dollar
= 1 means Euro

Command: Version request
------------------------
#V,R,0;
#v,-,8,<Model>,<Memory>,<HWMajor>,<HWminor>,<FWMajor>,<FWminor>,<FWtimestamp>,<Checksum>;
Command: Version request
Reply: Version information, including raw memory capacity (see #c,r reply).
Note: this is also the reply to any well-formatted but unrecognized command, e.g., #X,R,0;.
Example:
#v,-,8,1,65206,5,2,3,14,200612211910,0;
<Model>
0=Standard
1=PRO
2=ES
3=Ethernet
4=Blind Module
<Memory> Integer number of bytes of nonvolatile logging memory (EEPROM less calibration memory).
<HWMajor> Integer Hardware major version
5 = WattsUp redesign with ADE7763 and PIC18F45J10
<HWminor> Integer Hardware major version
0 = no USB
1 = 4MHz oscillator with USB serial at 19,200bps
2 = 3.6864MHz oscillator PLL'd x4 with USB serial at 115,200bps
<FWMajor> Integer Hardware major version, e.g. the 13 in 13.5
<FWminor> Integer Hardware major version, e.g., the 127 in 9.127
<FWtimestamp> Integer year, month, date, hour, minute, second of compilation, e.g., 200610312322.
<Checksum> Integer program memory checksum calculated on demand. (Unimplemented.)

Command: Soft restart
---------------------
#V,W,0;
Command: Soft restart
Notes: like power off/on; firmware program starts over leaving configuration memory intact

III. UNITS, FORMAT, AND RANGE FOR THE VALUES SENT FROM THE DATA LOG:
====================================================================
A. All arguments are integer values.

B. Most electrical values such as watts, volts, etc. are represented as tenths
of the basic unit. For example, watts would be represented as the number of
tenths of watts.

<W> Integer, watts * 10. (Tenths of watts); 0 - 50000 [2 bytes].

<V> Integer, volts * 10. (Tenths of volts); 900 - 2800 [2 bytes].

<A> Integer, amps * 10. (Thousandths of amps); 0 - 20000 [2 bytes].

<WH> Integer, watt-hours * 10. (Tenths of watt-hours); 0 - 2398800000 (= 5000W
* 24 hr/day * 1999 days * 10 tenths/unit) [4 bytes].

<Cost> Integer, mils. (Tenths of cents or other currency); 0 - 4294967296 (=
2^32-1; 5kW * 65500 mils/kW-hr * 24 hr/day * 546 days, or 5kW * 17900
mils/kW-hr * 24 hr/day * 1999 days, or 1366W * 65500 mils/kW-hr * 24 hr/day *
1999 days) [4 bytes].

<WH/Mo> Integer, Watt Hours (Units of WHrs); 0 - 3600000 (= 5000W * 24 hr/day *
30 day/mo) [3 bytes].

<Cost/Mo> Integer, mils (Tenths of cents or other currency); 0 - 235800000 (=
5kW * 65500 mils/kW-hr * 24 hr/day * 30 days) [4 bytes].

<PF> Power factor, percent ratio of Watts versus Volt Amps; 0 - 100 [1 byte].

<DC> Duty cycle, percent of the time on versus total time; 0 - 100 [1 byte].

<PC> Power Cycle: Integer, number of power-on events indicates that power was
removed at some point during this sampling interval since last memory clear; 0
- 255 [1 byte].

<HZ> Line Frequency, hertz * 10 (tenths of hertz), 400 - 700 [2 bytes].

<VA> Volt-Amps, VA * 10 (tenths of volt-amps); 0 - 50000 [2 bytes].